| Standard Home Inspection Report | |
| Client(s): | Sample Report |
| Property address: | Westinspect Eubank Inspections Accurate Independent Inspections Home - Commercial - Environmental |
| Inspection date: | 2010 |
Property ownership is both a privilege
and a responsibility. Take time to read the entire report.
Westinspect Eubank Inspections will be glad to answer your questions
after you have read the whole report, from beginning to end.
What
is the purpose of this property inspection?
![]() | REPAIR or REPLACE | Recommend repairing or replacing |
![]() | REPAIR or MAINTAIN | Recommend repair and/or maintenance |
![]() | MINOR DEFECT or FUTURE REPAIR | Recommend correction, but not urgent |
![]() | MAINTAIN | Recommend ongoing maintenance |
![]() | EVALUATE | Recommend evaluation by a specialist |
![]() | SERVICEABLE | Item or component is in serviceable condition |
![]() | COMMENT | For your information |
Click here for a glossary of building construction terms.
Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp| General information | Return to table of contents |
| Exterior | Return to table of contents |
The driveway had significant cracks and/or deterioration in the
southeast corner. Recommend repairing or replacing this section of
driveway. Other minor cracks were noted, and many had been repaired
with caulk. Recommend repairing all minor cracks with concrete caulk or
similar product.
See photo 2
The downspout extension at the southeast corner of the house was
ineffective, due to being located between two confining fence sections.
This will prevent water from flowing freely away from the house, and
can result in water accumulating around the structure's foundation.
Accumulated water is a conducive condition to wood destroying insects
and organisms, and may also cause the foundation to settle and possibly
fail over time. Repairs should be made as necessary, such as installing
or repositioning splash blocks, or installing and/or repairing tie-ins
to underground drain lines, so rain water is carried at least several
feet away from the structure to soil that slopes down and away from the
structure.
See photo 3
Three window wells below ground level did not have covers. This can
allow water to penetrate to the foundation or basement. Recommend
installing window well covers on all window wells. If window is located
at a room that will be used as a bedroom, then also recommend
installing hinges and a standard window well ladder, so that the window
well can be used as a fire escape.
See photo 4
This home was clad with composition wood fiber siding. Some areas of
siding on this structure showed symptoms of swelling, cracking, or
delamination, but it appeared that the siding had not deteriorated to
the point of needing replacement. Some manufacturers (Louisiana Pacific)
recommend a repair process for this siding where affected areas are
sealed with "Permanizer Plus", a flexible primer made by Pittsburgh
Paint, followed by two coats of 100% acrylic latex paint. This sealant
must be applied to the bottom edges using a brush. The face of the
siding can be sprayed. The "Permanizer Plus" sealer isn't required for
edges that aren't swollen, cracked or deteriorated, but the acrylic
latex should still be brushed on these edges. At a minimum, recommend
having a qualified contractor seal and repaint as described above, or by
other methods specified by the siding's manufacturer.
See photo 5
Random gaps were found between sections of siding. Gaps should be sealed
or caulked as necessary to prevent moisture intrusion and entry by
vermin.
See photo 6
One downspout terminated above roof surfaces rather than being routed to
gutters below or to the ground level. This is very common, but it can
reduce the life of roof surface materials below due to large amounts of
water frequently flowing over the roof surface. Granules typically are
washed off of composition shingles as a result, and leaks may occur.
Recommend considering having a qualified contractor install extensions
as necessary so downspouts don't terminate above roof surfaces.
See photo 8
A plastic bag was wrapped around the driveway light. The seller
reported that the bag keeps barn swallows from nesting in that fixture.
See photo 7
| Roof | Return to table of contents |
Debris had accumulated in one or more gutters. This is a conducive
condition for wood destroying insects since gutters may overflow and
cause water to come in contact with the structure's exterior or make
water accumulate around the foundation. Gutters should be cleaned now
and as necessary in the future.
Recommend resealing around all four skylights with roofing caulk, as a
standard precaution to avoid water intrusion. See line 25 below.
See photo 9
See photo 10
A small area of deterioration was found on the soffit of the upper level
on the west side. This appeared to be from a previous roof leak, and
was not a current concern. The current roof had no leak evidence at the
time of this inspection. No action is recommended at this time.
See photo 11
| Garage | Return to table of contents |
The automatic door closing device (sprung hinges, etc.) on the
garage-house door needs adjustment, repair or replacing. The door did
not close and latch easily and/or completely via the force of the
automatic closing device. This door is intended to prevent vehicle fumes
from entering living spaces and to slow the spread of fire from the
garage to living spaces. A qualified contractor should evaluate and make
repairs as necessary.
The vehicle door had an electric opener installed, and the manual lock
mechanism on the door had not been disabled. Damage or injury may occur
if the vehicle door opener is operated with the manual lock engaged. A
qualified contractor should disable or remove the lock mechanism. For
more information on garage door safety issues, visit: http://www.cpsc.gov/cpscpub/pubs/523.html or http://www.ohdstl.com/safety.html
See photo 13
Much of the garage, include areas around the interior perimeter and in
the center are excluded from this inspection due to lack of access from
stored items.
| Attic | Return to table of contents |
The ceiling insulation's R rating was slightly less than R-30 which is
recommended for this area. Recommend having a qualified contractor
install additional insulation as per standard building practices for
better energy efficiency.
| Electric service | Return to table of contents |
One screw was missing from the cover of the electric service panel.
Recommend replacing this screw so that panel cover completely protects
the enclosed wiring. Stock screws from the panel manufacturer should be
used, or their equivalent.
No concerns were found with the overall electrical system at the time of
this inspection.
| Water heater | Return to table of contents |
The estimated useful life for most water heaters is 8 to 12 years. This
water heater appeared to be approaching this age and may need replacing
at any time. Recommend budgeting for a replacement in the future.
| Heating and cooling | Return to table of contents |
The filters for the heating systems should be checked monthly and
replaced or washed as necessary.
The last service date of these systems appeared to be more than one year
ago, or the inspector was unable to determine the last service date.
The clients should ask the property owner when they were last serviced.
If unable to determine the last service date, or if these systems were
serviced more than one year ago, a qualified heating and cooling
contractor should inspect, clean, and service these systems, and make
repairs if necessary. For safety reasons, and because these systems are
fueled by gas or oil, this servicing should be performed annually in the
future. The brief visual observation by the home inspector is NOT a
substitute for the complete servicing that is recommended here. For more
information visit: http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
No concerns were found with the heating and cooling systems at the time
of this inspection.
See photo 12
| Plumbing and laundry | Return to table of contents |
No concerns were found with the overall plumbing system at the time of
this inspection.
| Fireplaces, woodstoves and chimneys | Return to table of contents |
This gas-log fireplace was operated by a remote control, and was working
properly at the time of this inspection.
| Basement | Return to table of contents |
| Bathrooms | Return to table of contents |
Upstairs bathroom with a shower did not have an exhaust fan installed.
Moisture accumulation will occur and may damage the structure. Even if
the bathroom has a window that opens, it likely does not provide
adequate ventilation, especially during cold weather when the window is
closed. A qualified contractor should install exhaust fans as per
standard building practices where missing in bathrooms with showers.
Basement shower handle was difficult to operate, requiring a lot of
force to turn on and off. Recommend replacing this shower handle.
| Interior rooms | Return to table of contents |
The skylight in the small front bathroom (near the front entry) showed
evidence of past leaking. Paint was bubbled and soft in two small
areas, and a thicker layer of caulk was noted around the interior edges
of the skylight. Recommend sealing around the exterior of this
skylight. See line 9 above. Recommend occasional monitoring to make
sure skylight does not leak during heavy rain or snow.
This structure was built in 1979 and may contain lead paint. Laws were
enacted in 1978 in the US preventing the use of lead paint in
residential structures. Lead is a known safety hazard, especially to
children but also to adults. The paint found in and around this
structure appeared to be intact and may be encapsulated by more recent
layers of paint that are not lead-based. Regardless, recommend following
precautions as described in the following links to Consumer Products
Safety Commission website articles regarding possible lead paint.| Additional recommendations & information | Return to table of contents |
This house meets the following requirements as required in HUD Handbooks
4905.1 and 4150.2: The house can be used and maintained individually
without trespass on adjoining properties. It has independent utilities.
It has safe and potable water. It has sanitary facilities with a safe
method of sewage disposal. The heating is adequate for healthful and
comfortable living conditions. The house has domestic hot water. It
has electricity for lighting and for equipment used in the living unit.
The property has vehicular or pedestrian access from a public or
private street. Access to the house is provided without passing through
any other living unit. There is no evidence of continuing settlement,
leakage, termites, excessive dampness, decay, or other conditions
impairing safety or sanitation of the dwelling.
OLDER HOME: We expect homes to be built according to the
standard practices and building codes, if any, that were in use at the
date of construction. Older homes often have areas or systems that do
not comply with current building codes. While this Inspection makes
every effort to point out safety concerns, it does not inspect for
building code compliance.
PUEBLO: For Pueblo City and County map information, see the
Pueblo County Geographic Information System (GIS) at http://www.gis.co.pueblo.co.us/.
Photos are included to help you better understand the condition
of the property at the time of the inspection. Photos are intended to
show an example of a concern, but they may not show every occurence and
may not accurately show its severity. Not every concern will have a
photo. Do not rely on photos alone.
Material defect is a condition with a real property or any
portion of it that would have a significant adverse impact on the value
of the real property or that involves an unreasonable risk to people on
the property. The fact that a structural element, system or subsystem is
near, at or beyond the end of the normal useful life of such a
structural element, system or subsystem is not by itself a material
defect.